arXiv.itsnick.co

an independent field guide to 23 million papers from arXiv & OpenAlex — not affiliated with arXiv.org

Author

Adam Wang

32 papers · 2013–2026

2013: 12014: 12015: 12016: 12017: 02018: 02019: 02020: 52021: 22022: 22023: 42024: 52025: 32026: 7
2013peak 7 in 20262026

Frequent co-authors

Papers

showing 1–25 of 32 RSS

Creation and perturbation of planar networks of chemical oscillators

Nathan Tompkins, Matthew Carl Cambria, Adam L. Wang +2 more

Computer Networks and Communications · Chaos An Interdisciplinary Journal of Nonlinear Science · · cited 22× · DOI ↗ · more like this ·

Methods for creating custom planar networks of diffusively coupled chemical oscillators and perturbing individual oscillators within the network are presented. The oscillators consist of the Belousov-Zhabotinsky (BZ) reaction contained in an emulsion. Networks of drops of the BZ reaction are created with either Dirichlet (constant-concentration) or Neumann (no-flux) boundary conditions in a custom planar configuration using programmable illumination for the perturbations. The differences between the observed network dynamics for each boundary condition are described. Using light, we demonstrate the ability to control the initial conditions of the network and to cause individual oscillators within the network to undergo sustained period elongation or a one-time phase delay.

Multiple organ segmentation for CT scout images

Kaylee Fang, Sen Wang, Maria Medrano +3 more

Computer Vision and Pattern Recognition · · cited 1× · DOI ↗ · more like this ·

CT scout images are used to plan the anatomic scan range and optimize radiation dose. This initial step customizes CT examinations to the individual patient and maximizes image quality while minimizing radiation exposure. For these exams to be fully personalized at the organ level, the precise location of the patient’s relevant anatomy within the CT scan range is of utmost importance. In this work, we investigate methods for the automatic segmentation of multiple organs from CT scout images. We use variations of a U-Net model with a ResNet-50 encoder backbone pretrained on ImageNet-1K, and examine their segmentation performance for frontal and lateral scout views. We demonstrate that automatic organ segmentation for scout images is a highly feasible and attractive task, with applications extending beyond CT exam planning to include radiograph-based surgical planning and guiding…

Simulation analysis of a direct/indirect conversion dual-layer X-ray detector for early identification of coronary artery calcium

Akyl Swaby, Linxi Shi, Kaitlin Hellier +2 more

physics.med-ph · · cited 0× · arXiv ↗ · more like this ·

Coronary artery calcification (CAC) is a strong predictor of future cardiovascular events, and CAC burden is commonly used to stratify patient cardiovascular risk. Although CAC is typically quantified using computed tomography, routine chest radiography offers an opportunity for lower-dose, widely available opportunistic screening. Single-exposure dual-energy chest radiography using multilayer flat-panel detectors can generate low- and high-energy images without motion artifacts and provide material decomposition parameters, including calcification density. In this work, we investigate a direct/indirect dual-layer detector consisting of an amorphous selenium (a-Se) direct-conversion top layer and a cesium iodide scintillator-based indirect-conversion bottom layer for enhanced visualization of small CAC. A cascaded linear systems model (CLSM) simulated task-based detectability for a 1 mm…

Toward opportunistic coronary artery calcium assessment from dual-layer dual-energy chest radiography using deep learning: a simulation study

Linxi Shi, Akyl Swaby, Kaitlin Hellier +5 more

physics.med-ph · · cited 0× · arXiv ↗ · more like this ·

Background: Coronary artery calcium (CAC) predicts cardiovascular risk. Dual-energy (DE) chest radiography may enable accessible opportunistic CAC assessment by separating calcifications from overlapping bone. Purpose: To evaluate multi-task deep learning for CAC localization and CT-referenced score prediction and assess projection, image representation, and exposure effects. Methods: This retrospective simulation study used 550 calcium-scoring CT exams with reference CAC masks and Agatston scores. Dual-layer DE radiographs were simulated with a physics-based detector model. A modified nnU-Net jointly predicted CAC localization and scores from continuous probability maps. Comparisons included AP, 45°, and lateral views; lateral single-energy (SE), DE bone, and high-pass filtered DE bone images; and dose-matched models at 70, 50, and 24 mAs. Patient-level splitting reserved 10% for…

Efficient Noise Context-Aware Representation for Low-Dose CT Denoising

Minwoo Yu, N. Robert Bennett, Jongduk Baek +1 more

cs.CV · · cited 0× · arXiv ↗ · more like this ·

While deep learning-based denoising has become widely adopted in low-dose CT, conventional models use generic architectures designed for natural images, failing to account for non-stationary and spatially correlated CT noise characteristics. To address this, we propose an Efficient Noise COntext-aware REpresentation (ENCORE) framework that explicitly leverages CT noise characteristics and anatomical features. First, we reformulate the noise synthesis procedure based on a realistic noise distribution beyond the conventional Gaussian approximation, establishing a rigorous foundation for training pair generation. Next, we extract local noise power and correlation contexts to guide the denoising process. To fully leverage the potential of noise context, we propose a FlyingConv module, which adaptively changes convolution weights for each local image region. Notably, our approach…

Evaluation of Silicon-Based Photon-Counting CT for Coronary Stenosis Quantification with Realistic Coronary Artery Phantoms

Maria Jose Medrano, Jed Pack, Stephen Araujo +5 more

physics.med-ph · · cited 0× · arXiv ↗ · more like this ·

Objective: To quantify the impact of high-resolution deep silicon photon-counting CT (dSi-PCCT) on coronary stenosis quantification in anatomically realistic calcified coronary artery phantoms using Micro-CT as ground truth. Methods: Twelve vessel sections representing four calcification geometries (Type I-IV) and three luminal iodine concentrations (10, 15, and 20 mg/mL) were scanned under static conditions using energy-integrating detector CT (EID-CT), dSi-PCCT, and Micro-CT. Images were registered to Micro-CT and segmented using an automated threshold-based pipeline. The primary analysis compared longitudinal profiles of Micro-CT-referenced percent area stenosis and segmented vessel area. A secondary analysis evaluated ellipse-derived percent area stenosis and percent vessel-area deviation at the maximum-calcification cross-section. Results: dSi-PCCT reduced whole-profile mean…

A remark on conditional entropy

Adam Wang

cs.IT · · cited 0× · arXiv ↗ · more like this ·

The following note proves that conditional entropy of a sequence is almost time-reversal invariant, specifically they only differ by a small constant factor dependent only upon the forward and backward models that the entropies are being calculated with respect to. This gives rise to a numerical value that quantifies learnability, as well as a methodology to control for distributional shift between datasets. Rough guidelines are given for practitioners.

Fairness-enhancing mixed effects deep learning improves fairness on in- and out-of-distribution clustered (non-iid) data

Son Nguyen, Adam Wang, Albert Montillo

cs.LG · · cited 0× · arXiv ↗ · more like this ·

Traditional deep learning (DL) models have two ubiquitous limitations. First, they assume training samples are independent and identically distributed (i.i.d), an assumption often violated in real-world datasets where samples have additional correlation due to repeat measurements (e.g., on the same participants in a longitudinal study or cells from the same sequencer). This leads to performance degradation, limited generalization, and covariate confounding, which induces Type I and Type II errors. Second, DL models typically prioritize overall accuracy, favoring accuracy on the majority while sacrificing performance for underrepresented subpopulations, leading to unfair, biased models. This is critical to remediate, particularly in models which influence decisions regarding loan approvals and healthcare. To address these issues, we propose the Fair Mixed Effects Deep Learning (Fair…

Predict Moves

Adam Wang, Steve Chang, John Wilson

cs.HC · · cited 0× · arXiv ↗ · more like this ·

Mobile applications and on-body devices are becoming increasingly ubiquitous tools for physical activity tracking. We propose utilizing a self-tracker's habits to support continuous prediction of whether they will reach their daily step goal, thus enabling a variety of potential persuasive interventions. Our aim is to improve the prediction by leveraging historical data and other qualitative (motivation for using the systems, location, gender) and, quantitative (age) features. We have collected datasets from two activity tracking platforms (Moves and Fitbit) and aim to check if the model we derive from one is generalizable over the other. In the following paper we establish a pipeline for extracting the data and formatting it for modeling. We discuss the approach we took and our findings while selecting the features and classification models for the dataset. We further discuss the…

Modelling nonlinear chemical oscillators with inhibitory coupling

Jacob Gold, Adam Wang, Camille Girabawe +2 more

Computer Networks and Communications · MDC Repository (Max-Delbrueck-Center for Molecular Medicine) · · cited 0× · DOI ↗ · more like this ·

We investigate the nonlinear, oscillatory Belousov-Zhabotinsky (BZ) reaction by constructing a computationally efficient Kuromoto-based model to predict its behavior. We treat each BZ droplet as a chemical oscillator that is coupled to its neighbors through diffusion and generate the coupling function used in our model. We then test our model with experimental data for a series of one-dimensional 60 micron diameter BZ droplets. The RMS error between the measured phases of the droplets and our simulation is 0.118 radians.

15th ICCRTS “The Evolution of C2” Modeling and Optimizing the Motivation of Workers and Managers for Knowledge-Sharing: A Game-Theoretic Analysis Topic 3: Information Sharing and Collaboration Processes and Behaviors

Chuan-min Adam Wang (student, Raymond E. Levitt, S. Ping Ho

Communication · · cited 0× · OpenAlex ↗ · more like this ·

Knowledge management (KM) is especially difficult to implement for project-based work. Tacit knowledge gained during projects diffuses when project teams disband and reform. Organizations are increasingly focusing on managing their knowledge flows, developing or investing in KM systems. Knowledge-sharing (KS) behaviors are the main input to KM systems, so we aim to optimize knowledge input to magnify the usefulness of KM systems. We adopt game-theoretic models to analyze workers ’ knowledge-sharing dynamics under different KM strategies, taking managers ’ viewpoints. We will solve Nash Equilibria by identifying associated conditions on each equilibrium path, and derive implications from these conditions for KM strategies. We will explore: (1) types of knowledge that deserve sharing; (2) types of employees that possess different knowledge; (3) incentives that cause the right individuals…

Liver Metastasis Detection at Reduced Radiation Dose: Diagnostic Evaluation of a Novel Organ-Level Tube Current Modulation Method

Maria Jose Medrano, Sen Wang, Kaylee W. Fang +8 more

physics.med-ph · · arXiv ↗ · more like this ·

Objective: To evaluate retroOpt, a novel organ-level tube current modulation (TCM) method that minimizes effective radiation dose while preserving diagnostic image quality for liver metastasis detection. Methods: In this retrospective, IRB-approved study, 22 patients with 68 liver lesions (38 malignant, 30 benign) underwent portal venous phase contrast-enhanced chest-abdomen-pelvis CT. Using projection-domain noise emulation, five series were generated per patient: original full dose (Orig-100), uniform dose reduction to 40% (UD-40) and 60% (UD-60) of the original effective dose, and organ-level TCM at the same levels (Opt-40, Opt-60). Three abdominal radiologists independently detected and classified lesions and rated image quality (5-point Likert). Per-lesion sensitivity was compared by McNemar test. Malignant lesion-size thresholds for 50% and 90% sensitivity (x50, x90) were…

Characterizing the Radiation Dose to Measurement Accuracy Relationship across Multiple Metrics in Opportunistic Chest CT

Boyuan Li, Carolyn C. Chang, Jake J. Kim +5 more

physics.med-ph · · arXiv ↗ · more like this ·

Objectives: This study aims to characterize the dose-performance relationship for opportunistic CT and disentangle the contributions of segmentation failure and dose-dependent HU bias to performance degradation. Methods: Simulated low-dose CT images at 1-75% of full dose were generated from 50 paired full- and low-dose chest CT scans. An independent dataset of 22 paired PCCT acquisitions at lung cancer screening (LCS) and chest x-ray-equivalent (CXR) dose levels provided parallel real-world evaluation. Multiple quantitative disease metrics were obtained using deep learning-based segmentation followed by quantitative metric extraction. Classification performance was evaluated against full-dose reference standards, with additional analyses isolating the contributions of segmentation error and HU bias. Agreement between dose levels was assessed using Bland-Altman and correlation analyses.…

End-to-End Differentiable Photon Counting CT

Sen Wang, Yirong Yang, Jooho Lee +2 more

physics.med-ph · · arXiv ↗ · more like this ·

Quantitative imaging is an important feature of spectral X-ray and CT systems, especially photon-counting CT (PCCT) imaging systems, which is achieved through material decomposition (MD) using spectral measurements. In this work, we present a novel framework that makes the PCCT imaging chain end-to-end differentiable (differentiable PCCT), with which we can leverage quantitative information in the image domain to enable cross-domain learning and optimization for upstream models. Specifically, the material decomposition from maximum-likelihood estimation (MLE) was made differentiable based on the Implicit Function Theorem and inserted as a layer into the imaging chain for end-to-end optimization. This framework allows for an automatic and adaptive solution of a wide range of imaging tasks, ultimately achieving quantitative imaging through computation rather than manual intervention. The…

Scout-Dose-TCM: Direct and Prospective Scout-Based Estimation of Personalized Organ Doses from Tube Current Modulated CT Exams

Maria Jose Medrano, Sen Wang, Liyan Sun +5 more

physics.med-ph · · arXiv ↗ · more like this ·

This study proposes Scout-Dose-TCM for direct, prospective estimation of organ-level doses under tube current modulation (TCM) and compares its performance to two established methods. We analyzed contrast-enhanced chest-abdomen-pelvis CT scans from 130 adults (120 kVp, TCM). Reference doses for six organs (lungs, kidneys, liver, pancreas, bladder, spleen) were calculated using MC-GPU and TotalSegmentator. Based on these, we trained Scout-Dose-TCM, a deep learning model that predicts organ doses corresponding to discrete cosine transform (DCT) basis functions, enabling real-time estimates for any TCM profile. The model combines a feature learning module that extracts contextual information from lateral and frontal scouts and scan range with a dose learning module that output DCT-based dose estimates. A customized loss function incorporated the DCT formulation during training. For…

Unsupervised Training of a Dynamic Context-Aware Deep Denoising Framework for Low-Dose Fluoroscopic Imaging

Sun-Young Jeon, Sen Wang, Adam S. Wang +2 more

eess.IV · · arXiv ↗ · more like this ·

Fluoroscopy is critical for real-time X-ray visualization in medical imaging. However, low-dose images are compromised by noise, potentially affecting diagnostic accuracy. Noise reduction is crucial for maintaining image quality, especially given such challenges as motion artifacts and the limited availability of clean data in medical imaging. To address these issues, we propose an unsupervised training framework for dynamic context-aware denoising of fluoroscopy image sequences. First, we train the multi-scale recurrent attention U-Net (MSR2AU-Net) without requiring clean data to address the initial noise. Second, we incorporate a knowledge distillation-based uncorrelated noise suppression module and a recursive filtering-based correlated noise suppression module enhanced with motion compensation to further improve motion compensation and achieve superior denoising performance.…

OpenDosimeter: Open Hardware Personal X-ray Dosimeter

Norah Ger, Alice Ku, Jasmyn Lopez +8 more

physics.ins-det · · arXiv ↗ · more like this ·

We present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry Pi Pico, OpenDosimeter provides real-time feedback (1 Hz), data logging (10 hours), and battery-powered operation. One of the core innovations is that we calibrate the device using $^{241}$Am found in ionization smoke detectors. Specifically, we use the $γ$-emissions to spectrally calibrate the dosimeter, then calculate the effective dose from X-ray exposure by compensating for the scintillator absorption efficiency and applying energy-to-dose coefficients derived from tabulated data in the ICRP 116 publication. We demonstrate that this transparent approach enables real-time dose rate readings with a linear response between 0.1-1000 $μ$Sv/h at…

PFCM: Poisson flow consistency models for low-dose CT image denoising

Dennis Hein, Grant Stevens, Adam Wang +1 more

eess.IV · · arXiv ↗ · more like this ·

X-ray computed tomography (CT) is widely used for medical diagnosis and treatment planning; however, concerns about ionizing radiation exposure drive efforts to optimize image quality at lower doses. This study introduces Poisson Flow Consistency Models (PFCM), a novel family of deep generative models that combines the robustness of PFGM++ with the efficient single-step sampling of consistency models. PFCM are derived by generalizing consistency distillation to PFGM++ through a change-of-variables and an updated noise distribution. As a distilled version of PFGM++, PFCM inherit the ability to trade off robustness for rigidity via the hyperparameter $D \in (0,\infty)$. A fact that we exploit to adapt this novel generative model for the task of low-dose CT image denoising, via a ``task-specific'' sampler that ``hijacks'' the generative process by replacing an intermediate state with the…

A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT

Jed D. Pack, Paul Fitzgerald, Stephen Araujo +7 more

physics.med-ph · · arXiv ↗ · more like this ·

While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more accurate delineation between calcified plaque and coronary vessel lumen. A new set of vessel phantoms has been designed and manufactured for quantifying this improvement. Comparisons are made between an existing clinical CT system, a prototype photon counting system, with images from a micro CT system being used as the gold standard. Scans were made of the same objects on all three systems. The resulting images were registered and the luminal cross section areas were compared. Luminal…

Scout-Net: Prospective Personalized Estimation of CT Organ Doses from Scout Views

Abdullah-Al-Zubaer Imran, Sen Wang, Debashish Pal +4 more

cs.CV · · arXiv ↗ · more like this ·

Purpose: Estimation of patient-specific organ doses is required for more comprehensive dose metrics, such as effective dose. Currently, available methods are performed retrospectively using the CT images themselves, which can only be done after the scan. To optimize CT acquisitions before scanning, rapid prediction of patient-specific organ dose is needed prospectively, using available scout images. We, therefore, devise an end-to-end, fully-automated deep learning solution to perform real-time, patient-specific, organ-level dosimetric estimation of CT scans. Approach: We propose the Scout-Net model for CT dose prediction at six different organs as well as for the overall patient body, leveraging the routinely obtained frontal and lateral scout images of patients, before their CT scans. To obtain reference values of the organ doses, we used Monte Carlo simulation and 3D segmentation…

Coronary Atherosclerotic Plaque Characterization with Photon-counting CT: a Simulation-based Feasibility Study

Mengzhou Li, Mingye Wu, Jed Pack +5 more

physics.med-ph · · arXiv ↗ · more like this ·

Recent development of photon-counting CT (PCCT) brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on detectors made of CZT or CdTe materials, deep-silicon photon-counting detectors have unique performance characteristics and promise distinct imaging capabilities. In this work, we report a systematic simulation study of a deep-silicon PCCT scanner with a new clinically-relevant digital plaque phantom with realistic geometrical parameters and chemical compositions. This work investigates the effects of spatial resolution, noise, motion artifacts, radiation dose, and spectral characterization. Our simulation results suggest that the deep-silicon PCCT design provides adequate spatial resolution for visualizing a necrotic core and quantitation of key…

Semi-Supervised Relational Contrastive Learning

Attiano Purpura-Pontoniere, Demetri Terzopoulos, Adam Wang +1 more

cs.CV · · arXiv ↗ · more like this ·

Disease diagnosis from medical images via supervised learning is usually dependent on tedious, error-prone, and costly image labeling by medical experts. Alternatively, semi-supervised learning and self-supervised learning offer effectiveness through the acquisition of valuable insights from readily available unlabeled images. We present Semi-Supervised Relational Contrastive Learning (SRCL), a novel semi-supervised learning model that leverages self-supervised contrastive loss and sample relation consistency for the more meaningful and effective exploitation of unlabeled data. Our experimentation with the SRCL model explores both pre-train/fine-tune and joint learning of the pretext (contrastive learning) and downstream (diagnostic classification) tasks. We validate against the ISIC 2018 Challenge benchmark skin lesion classification dataset and demonstrate the effectiveness of our…

Multi-Energy Blended CBCT Spectral Imaging Using a Spectral Modulator with Flying Focal Spot (SMFFS)

Yifan Deng, Hao Zhou, Zhilei Wang +2 more

physics.med-ph · · arXiv ↗ · more like this ·

Conventional cone-beam CT (CBCT) can be easily compromised by scatter and beam hardening artifacts, and the entanglement of scatter and spectral effects introduces additional complexity. In this work, we present the first attempt to develop a stationary spectral modulator with flying focal spot (SMFFS) technology as a promising, low-cost approach to accurately solving the X-ray scattering problem and physically enabling spectral imaging in a unified framework. To deal with the intertwined scatter-spectral challenge, we propose a novel scatter-decoupled material decomposition (SDMD) method for SMFFS based on a hypothesis of scatter similarity. Monte Carlo simulations of a pure-water cylinder phantom with different focal spot deflections show that focal spot deflections within a range of ~2 mm share quite similar scatter distributions overall. Numerical simulations using a clinical…

Single-Shot Quantitative X-ray Imaging Using a Primary Modulator and Dual-Layer Detector

Linxi Shi, N. Robert Bennett, Alexander Vezeridis +2 more

physics.med-ph · · arXiv ↗ · more like this ·

Purpose: Conventional x-ray imaging and fluoroscopy have limitations in quantitation due to several challenges, including scatter, beam hardening, and overlapping tissues. In this work, we propose single-shot quantitative imaging (SSQI) by combining the use of a primary modulator (PM) and dual-layer (DL) detector, which enables motion-free dual-energy (DE) imaging with scatter correction in a single shot. Methods: The SSQI algorithm allows simultaneous recovery of two material-specific images and two scatter images using four sub-measurements from the PM encoding. For validation, we set up SSQI on our tabletop system and imaged acrylic and copper slabs with known thicknesses, estimated scatter with our SSQI algorithm, and compared the material decomposition (MD) for different combinations of the two materials with ground truth. Second, we imaged an anthropomorphic chest phantom…