arXiv.itsnick.co

an independent field guide to 23 million papers from arXiv & OpenAlex — not affiliated with arXiv.org

Author

Alice T. Ku

2 papers · 1970–2024

1970: 11971: 01972: 01973: 01974: 01975: 01976: 01977: 01978: 01979: 01980: 01981: 01982: 01983: 01984: 01985: 01986: 01987: 01988: 01989: 01990: 01991: 01992: 01993: 01994: 01995: 01996: 01997: 01998: 01999: 02000: 02001: 02002: 02003: 02004: 02005: 02006: 02007: 02008: 02009: 02010: 02011: 02012: 02013: 02014: 02015: 02016: 02017: 02018: 02019: 02020: 02021: 02022: 02023: 02024: 1
1970peak 1 in 19702024

Frequent co-authors

Papers

showing 1–2 of 2 RSS

Stable carbonium ions. CV. Protonation of sulfoxides and sulfones in fluorosulfuric acid-antimony pentafluoride-sulfuryl chloride fluoride solution

George A. Olah, Alice T. Ku, Judith A. Olah

Information Systems · The Journal of Organic Chemistry · · cited 25× · DOI ↗ · more like this ·

ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTStable carbonium ions. CV. Protonation of sulfoxides and sulfones in fluorosulfuric acid-antimony pentafluoride-sulfuryl chloride fluoride solutionGeorge A. Olah, Alice T. Ku, and Judith A. OlahCite this: J. Org. Chem. 1970, 35, 11, 3904–3908Publication Date (Print):November 1, 1970Publication History Published online1 May 2002Published inissue 1 November 1970https://pubs.acs.org/doi/10.1021/jo00836a070https://doi.org/10.1021/jo00836a070research-articleACS PublicationsRequest reuse permissionsArticle Views166Altmetric-Citations22LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this…

OpenDosimeter: Open Hardware Personal X-ray Dosimeter

Norah Ger, Alice Ku, Jasmyn Lopez +8 more

physics.ins-det · · arXiv ↗ · more like this ·

We present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry Pi Pico, OpenDosimeter provides real-time feedback (1 Hz), data logging (10 hours), and battery-powered operation. One of the core innovations is that we calibrate the device using $^{241}$Am found in ionization smoke detectors. Specifically, we use the $γ$-emissions to spectrally calibrate the dosimeter, then calculate the effective dose from X-ray exposure by compensating for the scintillator absorption efficiency and applying energy-to-dose coefficients derived from tabulated data in the ICRP 116 publication. We demonstrate that this transparent approach enables real-time dose rate readings with a linear response between 0.1-1000 $μ$Sv/h at…