arXiv.itsnick.co

an independent field guide to 23 million papers from arXiv & OpenAlex — not affiliated with arXiv.org

Author

Michael Fitzpatrick

90 papers · 1976–2025

1976: 11977: 11978: 11979: 11980: 01981: 01982: 01983: 01984: 01985: 01986: 11987: 01988: 31989: 21990: 01991: 01992: 21993: 01994: 21995: 41996: 51997: 31998: 41999: 12000: 02001: 32002: 12003: 32004: 12005: 42006: 02007: 32008: 22009: 42010: 92011: 02012: 12013: 22014: 12015: 42016: 72017: 22018: 22019: 32020: 12021: 12022: 12023: 02024: 32025: 1
1976peak 9 in 20102025

Frequent co-authors

Papers

showing 1–25 of 90 RSS

Registration of head volume images using implantable fiducial markers

Calvin R. Maurer, J. Michael Fitzpatrick, M.Y. Wang +3 more

Computer Vision and Pattern Recognition · IEEE Transactions on Medical Imaging · · cited 568× · DOI ↗ · more like this ·

In this paper, we describe an extrinsic-point-based, interactive image-guided neurosurgical system designed at Vanderbilt University, Nashville, TN, as part of a collaborative effort among the Departments of Neurological Surgery, Computer Science, and Biomedical Engineering. Multimodal image-to-image (II) and image-to-physical (IP) registration is accomplished using implantable markers. Physical space tracking is accomplished with optical triangulation. We investigate the theoretical accuracy of point-based registration using numerical simulations, the experimental accuracy of our system using data obtained with a phantom, and the clinical accuracy of our system using data acquired in a prospective clinical trial by six neurosurgeons at four medical centers from 158 patients undergoing craniotomies to resect cerebral lesions. We can determine the position of our markers with an error of…

Registration of head CT images to physical space using a weighted combination of points and surfaces [image-guided surgery]

Calvin R. Maurer, Robert J. Maciunas, J. Michael Fitzpatrick

Computer Vision and Pattern Recognition · IEEE Transactions on Medical Imaging · · cited 162× · DOI ↗ · more like this ·

Most previously reported registration techniques that align three-dimensional image volumes by matching geometrical features such as points or surfaces use a single type of feature. We recently reported a hybrid registration technique that uses a weighted combination of multiple geometrical feature shapes. In this study we use the weighted geometrical feature (WGF) algorithm to register computed tomography (CT) images of the head to physical space using the skin surface only, the bone surface only, and various weighted combinations of these surfaces and one fiducial point (centroid of a bone-implanted marker). We use data acquired from 12 patients that underwent temporal lobe craniotomies for the resection of cerebral lesions. We evaluate and compare the accuracy of the registrations obtained using these various approaches by using as a reference gold standard the registration obtained…

On the generation of skeletons from discrete Euclidean distance maps

Yaorong Ge, J. Michael Fitzpatrick

Computer Vision and Pattern Recognition · IEEE Transactions on Pattern Analysis and Machine Intelligence · · cited 154× · DOI ↗ · more like this ·

The skeleton is an important representation for shape analysis. A common approach for generating discrete skeletons takes three steps: 1) computing the distance map, 2) detecting maximal disks from the distance map, and 3) linking the centers of maximal disks (CMDs) into a connected skeleton. Algorithms using approximate distance metrics are abundant and their theory has been well established. However, the resulting skeletons may be inaccurate and sensitive to rotation. In this paper, we study methods for generating skeletons based on the exact Euclidean metric. We first show that no previous algorithms identify the exact set of discrete maximal disks under the Euclidean metric. We then propose new algorithms and show that they are correct. To link CMDs into connected skeletons, we examine two prevalent approaches: connected thinning and steepest ascent. We point out that the connected…

Image registration.

Joaien P W Pluim, J. Michael Fitzpatrick

Computer Vision and Pattern Recognition · PubMed · · cited 151× · DOI ↗ · more like this ·

In order to demonstrate the growth of the medical image registration field over the past decades, this paper presents the number of journal publications on this topic since 1988 until 2002. In a similar manner, trends in topics within the field of medical image registration are detected. Publications on computed tomography (CT) and magnetic resonance imaging (MRI) are rather constant through the years. Positron emission tomography (PET) and single photon emission computed tomography (SPECT), on the other hand, seem to loose ground to newly emerging functional imaging techniques, such as functional MRI (fMRI) whereas an increase in interest in registration of ultrasound (US) images was observed. Two topics in image registration that are currently considered hot are intraoperative and elastic registration. Although the interest in intraoperative registration strongly increased in the late…

Registration of 3-D images using weighted geometrical features

Calvin R. Maurer, Georges B. Aboutanos, Benoît M. Dawant +2 more

Computer Vision and Pattern Recognition · IEEE Transactions on Medical Imaging · · cited 139× · DOI ↗ · more like this ·

The authors present a weighted geometrical feature (WGF) registration algorithm. Its efficacy is demonstrated by combining points and a surface. The technique is an extension of Besl and McKay's (1992) iterative closest point (ICP) algorithm. The authors use the WGF algorithm to register X-ray computed tomography (CT) and T2-weighted magnetic resonance (MR) volume head images acquired from eleven patients that underwent craniotomies in a neurosurgical clinical trial. Each patient had five external markers attached to transcutaneous posts screwed into the outer table of the skull. The authors define registration error as the distance between positions of corresponding markers that are not used for registration. The CT and MR images are registered using fiducial paints (marker positions) only, a surface only, and various weighted combinations of points and a surface. The CT surface is…

Fiducial registration error and target registration error are uncorrelated

J. Michael Fitzpatrick

Computer Vision and Pattern Recognition · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · · cited 134× · DOI ↗ · more like this ·

Image-guidance systems based on fiducial registration typically display some measure of registration accuracy based on the goodness of fit of the fiducials. A common measure is fiducial registration error (FRE), which equals the root-meansquare error in fiducial alignment between image space and physical space. It is natural for the surgeon to regard the displayed estimate of error as an indication of the accuracy of the system's ability to provide guidance to surgical targets for a given case. Thus, when the estimate is smaller than usual, it may be assumed that the target registration error (TRE) is likely to be smaller than usual. We show that this assumption, while intuitively convincing, is in fact wrong. We show it in two ways. First, we prove to first order that for a given system with a given level of normally distributed fiducial localization error, all measures of goodness of…

Retrospective intermodality registration techniques for images of the head: surface-based versus volume-based

Jay B. West, J. Michael Fitzpatrick, M.Y. Wang +4 more

Computer Vision and Pattern Recognition · IEEE Transactions on Medical Imaging · · cited 133× · DOI ↗ · more like this ·

The primary objective of this study is to perform a blinded evaluation of two groups of retrospective image registration techniques, using as a gold standard a prospective marker-based registration method, and to compare the performance of one group with the other. These techniques have already been evaluated individually [27]. In this paper, however, we find that by grouping the techniques as volume based or surface based, we can make some interesting conclusions which were not visible in the earlier study. In order to ensure blindness, all retrospective registrations were performed by participants who had no knowledge of the gold-standard results until after their results had been submitted. Image volumes of three modalities: X-ray computed tomography (CT), magnetic resonance (MR), and positron emission tomography (PET) were obtained from patients undergoing neurosurgery at Vanderbilt…

The role of registration in accurate surgical guidance

J. Michael Fitzpatrick

Computer Vision and Pattern Recognition · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · · cited 110× · DOI ↗ · more like this ·

Registration is presented as the central issue of surgical guidance. The focus is on the accuracy of approaches employed today, all of which use pre-operative images to guide surgery on rigid anatomy. The three most well-established approaches to guidance, namely the stereotactic frame, point fiducials, and surface matching, are examined in detail, together with two new approaches based on microstereotactic frames. It is shown that each method relies on the registration of points in the image to corresponding points in the operating room, and therefore that the error patterns associated with point registration are similar for all of them. Three types of registration error, namely fiducial localization error (FLE), fiducial registration error (FRE), and target registration error (TRE), are highlighted, as well as two additional guidance errors, namely target localization error and total…

Technical Note. Effect of Geometrical Distortion Correction in MR on Image Registration Accuracy

Calvin R. Maurer, Georges B. Aboutanos, Benoît M. Dawant +4 more

Computer Vision and Pattern Recognition · Journal of Computer Assisted Tomography · · cited 105× · DOI ↗ · more like this ·

In this article we investigate the effect of geometrical distortion correction in MR images on the accuracy of the registration of X-ray CT and MR head images for both a fiducial marker (extrinsic point) method and a surface-matching technique. We use CT and T2-weighted MR image volumes acquired from seven patients who underwent craniotomies in a stereotactic neurosurgical clinical trial. Each patient had four external markers attached to transcutaneous posts screwed into the outer table of the skull. The MR images are corrected for static field inhomogeneity by using an image rectification technique and corrected for scale distortion (gradient magnitude uncertainty) by using an attached stereotactic frame as an object of known shape and size. We define target registration error (TRE) as the distance between corresponding marker positions after registration and transformation. The…

The Air Pollution Experience and Physical Aggression<sup>1</sup>

James Rotton, James H. Frey, Timothy Barry +2 more

Sociology and Political Science · Journal of Applied Social Psychology · · cited 94× · DOI ↗ · more like this ·

Sixty undergraduate males delivered electric shocks to a confederate as punishment for making errors on a learning task. Half did so after being exposed to an aggressive model, whereas the other half did so without being exposed. Shocks were delivered from a room whose atmosphere was either unpolluted or contaminated by a moderately unpleasant odor (ethyl mercoptan) or an extremely obnoxious stench (ammonium sulfide). As hypothesized, the moderately unpleasant pollutant facilitated higher levels of aggression than either the extremely obnoxious one or the absence of pollution. However, contrary to a second hypothesis, pollution facilitated aggression only in the model's absence. The confirmation of the first hypothesis was interpreted as supporting and extending the affect‐aggression model from heat research. It was speculated that disconfirmation of the second hypothesis resulted…

Vaccine: The Controversial Story of Medicine's Greatest Lifesaver

Arthur W. Allen, Michael Fitzpatrick

Health · Journal of the Royal Society of Medicine · · cited 89× · DOI ↗ · more like this ·

In his comprehensive survey of vaccination controversies past and present, Arthur Allen quotes US vaccine chief Walter Orenstein's recollection that ‘for those trained in pediatrics in the 1970s, Hib (Haemophilus influenzae type b) was a horror.’ It was indeed. I recall a mother whose infant died of Hib meningitis, secondary to an apparently trivial otitis media, within minutes of arriving in hospital. Already at an advanced stage of her second pregnancy, she promptly went into labour and had an uncomplicated delivery. The way her grief at the loss of one child overwhelmed her joy at the arrival of another is my enduring memory of the horror of Hib, which was still killing 60 children every year in Britain in the 1980s. Thanks to the introduction of routine Hib immunization in 1992, this disease has now become a rarity. Yet, as Orenstein points out, when the immunization was…

&lt;title&gt;Registration of head volume images using implantable fiducial markers&lt;/title&gt;

Calvin R. Maurer, J. Michael Fitzpatrick, Matthew Y. Wang +3 more

Computer Vision and Pattern Recognition · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · · cited 75× · DOI ↗ · more like this ·

In this paper, we describe an extrinsic point-based, interactive image-guided neurosurgical system designed at Vanderbilt University as part of a collaborative effort among the departments of neurological surgery, computer science, and biomedical engineering. Multimodal image-to- image and image-to-physical registration is accomplished using implantable markers. Physical space tracking is accomplished with optical triangulation. We investigate the theoretical accuracy of point-based registration using numerical simulations, the experimental accuracy of our system using data obtained with a phantom, and the clinical accuracy of our system using data acquired in a prospective clinical trial by six neurosurgeons at four medical centers from 158 patients undergoing craniotomies to resect cerebral lesions. We can determine the position of our markers with an error of approximately 0.4 mm in…

Adaptive search space scaling in digital image registration

V.R. Mandava, J. Michael Fitzpatrick, David R. Pickens

Computer Vision and Pattern Recognition · IEEE Transactions on Medical Imaging · · cited 75× · DOI ↗ · more like this ·

An image registration technique for application in X-ray, gamma-ray, and magnetic resonance imaging is described. The technique involves searching a real-valued, multidimensional, rectangular, symmetric space of bilinear geometrical transformations for a globally optimal transformation. Physical considerations provide theoretical limits on the search space, but the theoretically maximum allowable space is still often much larger than the smallest rectangular symmetric subspace that contains the optimal transformation. To reduce the search time, the current practice is to guess an optimal subspace from the maximum allowable space. This reduced space is then discretized and searched. An automatic technique to estimate adaptively a subspace from the maximum space during the search process itself is described. This adaptive technique is tested with two quite different types of search…

Randomized controlled trial of plain English and visual abstracts for disseminating surgical research via social media

Stephen J. Chapman, R C Grossman, Michael Fitzpatrick +1 more

Health · British journal of surgery · · cited 53× · DOI ↗ · more like this ·

BACKGROUND: Patients are increasingly taking an active role in the design and delivery of surgical research. Public communication of results should also be encouraged, but this is often limited to non-expert commentary. This study assessed the role of plain English abstracts disseminated via social media in engaging patients and clinicians in the communication of surgical research. METHODS: A three-arm randomized controlled trial with crossover of two intervention arms was performed. Manuscripts accepted for publication in BJS were allocated to one of three arms and disseminated via Twitter: plain English abstracts, visual abstracts and standard tweets. The primary outcome was online engagement (a composite of tweets, replies and likes) by members of the public within 14 days. The secondary outcome was online engagement by healthcare professionals. RESULTS: Forty-one manuscripts were…

&lt;title&gt;Registration of multimodal volume head images via attached markers&lt;/title&gt;

V.R. Mandava, J. Michael Fitzpatrick, Calvin R. Maurer +2 more

Computer Vision and Pattern Recognition · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · · cited 50× · DOI ↗ · more like this ·

We investigate the accuracy of registering arbitrarily oriented, multimodal, volume images of the human head, both to other images and to physical space, by aligning a configuration of three or more fiducial points that are the centers of attached markers. To compute the centers we use an extension of an adaptive thresholding algorithm due to Kittler. Because the markers are indistinguishable it is necessary to establish their correspondence between images. We have evaluated geometric matching algorithms for this purpose. The inherent errors in fiducial localization arising with digital images limits the accuracy with which anatomical targets can be registered. To accommodate this error we apply a least-squares registration algorithm to the fiducials. To evaluate the resulting target registration accuracy we have conducted experiments on images of internally implanted markers in a…

Correcting Scaling Errors in Tomographic Images Using a Nine Degree of Freedom Registration Algorithm

David Hill, Calvin R. Maurer, Colin Studholme +2 more

Computer Vision and Pattern Recognition · Journal of Computer Assisted Tomography · · cited 46× · DOI ↗ · more like this ·

PURPOSE: Clinical imaging systems, especially MR scanners, frequently have errors of a few percent in their voxel dimensions. We evaluate a nine degree of freedom registration algorithm that maximizes mutual information for determining scaling errors. We evaluate it by registering MR and CT images for each of five patients (patient scaling) and by registering MR images of a phantom to a computer model of the phantom (phantom scaling). METHOD: Each scaling method was validated using bone-implanted markers localized in the patient images and also intraoperatively. The root mean square residual in the alignment of the fiducial markers [fiducial registration error (FRE)] was determined without scale correction, with patient scaling, and with phantom scaling. RESULTS: Each scaling method significantly reduced the average FRE (p < 0.05) for MR to CT registration and for MR to physical space…

Bringing Evidence-Based Self-Directed Intervention Practices to the Trenches for Students With Emotional and Behavioral Disorders

Michael Fitzpatrick, Earle Knowlton

Education · Preventing School Failure Alternative Education for Children and Youth · · cited 44× · DOI ↗ · more like this ·

Students with an emotional and behavioral disorder (EBD) often present complex challenges for schools, families, and society. Researchers have indicated that these problems are prevalent across the life span. This article addresses (a) the educational implications of the research-to-practice gap for students identified as having an EBD, (b) effective evidence-based self-directed intervention strategies that can be incorporated into classroom settings, (c) technology integration to assist practitioners in implementing self-directed intervention strategies, and (d) recommendations for integrating technology to enhance academic and social outcomes for students identified as having an EBD.

Lessons Learned in the Design and Delivery of an Introductory Programming MOOC

J. Michael Fitzpatrick, Ákos Lédeczi, Gayathri Narasimham +5 more

Computer Science Applications · · cited 41× · DOI ↗ · more like this ·

This paper describes the design and delivery of a highly successful MOOC that uses MATLAB to teach introductory computer programming to a wide audience. The decisions behind the curriculum and assessment strategy are detailed, and the results are evaluated based on three sessions of the course that saw 80,000 active students, two million lecture views and 100,000 auto-graded programming assignment sets during the three sessions delivered in 2015.

Evidence of Harm. Mercury in Vaccines and the Autism Epidemic: Medical Controversy

Michael Fitzpatrick

Health · BMJ · · cited 41× · DOI ↗ · more like this ·

W hen Andrew Wakefield, the former Royal Free Hospital researcher who launched the scare about a link between the measles, mumps, and rubella (MMR) vaccine and autism in Britain, claimed that he had learnt everything he knew about autism from parents, this sounded merely disingenuous. In David Kirby's case, unfortunately, it appears to be true: he seems to take at face value every claim made by campaigning parents in the United States who believe that vaccines containing the mercury based preservative thiomersal caused their children to become autistic. David Kirby St Martin's Press, $26.95/$C38.95, pp 480 ISBN 0 312 32644 0 www.stmartins.com/ Rating:![Graphic][1]</img>![Graphic][2]</img>![Graphic][3]</img>![Graphic][4]</img> But parents may not be reliable guides. Kirby faithfully records one mother's account of how she brought her son from the United States to see Dr Wakefield at the…

&lt;title&gt;Intersubject brain image registration using both cortical and subcortical landmarks&lt;/title&gt;

Yaorong Ge, J. Michael Fitzpatrick, Robert Kessler +2 more

Computer Vision and Pattern Recognition · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · · cited 36× · DOI ↗ · more like this ·

Intersubject registration of brain images involves localizing a set of easily detectable common features, matching these features, and finding a transformation that establishes a one-to-one correspondence of two image volumes from different subjects. Several different features and different methods for finding transformations have been described in the literature. A drawback common to the existing methods is that no, or few, features in the brain cortex are used. This paper studies the importance of incorporating such landmarks in brain registration. We apply a previously reported method to localize cortical convolutions in magnetic resonance images. We then derive a set of cortical landmarks from the traces representing the localized convolutions. Adding these cortical landmarks to a set of primarily subcortical landmarks proposed in an existing method, we compute matching…

On separation axioms for certain types of ordered topological space

D. C. J. Burgess, Michael E. Fitzpatrick

Algebra and Number Theory · Mathematical Proceedings of the Cambridge Philosophical Society · · cited 36× · DOI ↗ · more like this ·

An ordered topological space ( E , τ, ≥) is a set E endowed with a topology τ and a partial order ≥. For such a space order separation axioms have been studied by Nachbin (6) and McCartan (3). In this paper we discuss the consequences for these axioms of the imposition, in turn, of four conditions on ( E , τ, ≥), namely convexity (6), continuity, anticontinuity and bicontinuity (5).

&lt;title&gt;Registration of CT and MR brain images using a combination of points and surfaces&lt;/title&gt;

Calvin R. Maurer, Georges B. Aboutanos, Benoît M. Dawant +3 more

Computer Vision and Pattern Recognition · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · · cited 27× · DOI ↗ · more like this ·

In this paper we present a hybrid registration technique that uses a weighted combination of several feature shapes, e.g. points and surfaces. The technique is a modification of Besl &amp; McKay's iterative closest point (ICP) algorithm (IEEE Trans. Pattern Anal. Mach. Intell., 14:239-256, 1992). We use the technique to register x-ray computed tomography (CT) and T2-weighted magnetic resonance (MR) volume head images acquired from eleven patients that underwent craniotomies in a neurosurgical clinical trial. Each patient had five external markers attached to transcutaneous posts screwed into the outer table of the skull. We define registration error as the distance between corresponding marker positions after registration and transformation. The CT and MR images are registered using points (marker positions) only, surfaces only, and a weighted combination of points and surfaces. The CT…

Accurate localization of cortical convolutions in MR brain images

Yaorong Ge, J. Michael Fitzpatrick, Benoît M. Dawant +3 more

Computer Vision and Pattern Recognition · IEEE Transactions on Medical Imaging · · cited 26× · DOI ↗ · more like this ·

Analysis of brain images often requires accurate localization of cortical convolutions. Although magnetic resonance (MR) brain images offer sufficient resolution for identifying convolutions in theory, the nature of tomographic imaging prevents clear definition of convolutions in individual slices. Existing methods for solving this problem rely on heuristic adaptation of brain atlases created from a small number of individuals. These methods do not usually provide high accuracy because of large biological variations among individuals. The authors propose to localize convolutions by linking realistic visualizations of the cortical surface with the original image volume. They have developed a system so that a user can quickly localize key convolutions in several visualizations of an entire brain surface. Because of the links between the visualizations and the original volume, these…

Retrospective Registration of PET and MR Brain Images

Yaorong Ge, J. Michael Fitzpatrick, John R. Votaw +4 more

Computer Vision and Pattern Recognition · Journal of Computer Assisted Tomography · · cited 26× · DOI ↗ · more like this ·

OBJECTIVE: We present a validation study of an algorithm for retrospective registration of PET and MR brain images. MATERIALS AND METHODS: This algorithm involves two steps. In the first step, the two volumes are reformatted by aligning their interhemispheric fissure planes (midsagittal plane). In the second step, the corresponding planes parallel to the midsagittal plane are further aligned in the reformatted volumes to produce a 3D rigid body registration of the two original volumes. It is an efficient algorithm because both steps are performed in 2D spaces, and in each step only a small number of landmarks are required. A user-friendly system has been implemented to facilitate easy and fast processing of registration and reformatting of image volumes. The accuracy of this algorithm is validated using clinical scans of neurosurgical patients with a stereotaxic frame attached to their…

Working With American Indian Students and Families

Cornel Pewewardy, Michael Fitzpatrick

Education · Intervention in School and Clinic · · cited 25× · DOI ↗ · more like this ·

Although most American Indian students are educated in the public school system, there is limited literature regarding (a) how general and special educators can effectively meet the unique educational needs of these students or (b) what strategies educators can use while working with their families. Additionally, there are limited resources available regarding how American Indians view special education, disability issues, and the relationship between school and family. The worldview of American Indians differs from mainstream America, which has led to the overrepresentation of American Indian students in special education programs. This article provides culturally responsive research-based practices to help foster school and family relationships and improve the educational outcomes of American Indian students.