M. Sabry-Rizk

7 papers · 1995–2005

1995: 21996: 11997: 01998: 01999: 02000: 02001: 02002: 32003: 02004: 02005: 1
1995peak 3 in 20022005

Frequent co-authors

Papers

showing 1–7 of 7 RSS

Third-order cumulant signature matching technique for non-invasive fetal heart beat identification

M. Sabry-Rizk, Walid Zgallai, Paul Hardiman +1 more

Signal Processing · · cited 10× · DOI ↗ · more like this ·

This paper utilises the distinctive transient pulse feature of the third-order cumulant diagonal slice (TOCDS) of ECG signals to detect the number of occurrences of fetal heart beats during each of the maternal cycles. The fetal ECG signal is a comparatively weak signal (less than 20 percent of the mother ECG) and often embedded in noise. The fetal heart rate (FHR) lies in the range from 1.3 Hz to 3.5 Hz and it is possible for the mother and some of the fetal ECG signals to be closely overlapping. The paper also addresses the problem of false alarm situations often arising in diagonal-cumulant-slice recording during labour due to non-Gaussian impulsive or transient noise types and shows some results obtained after Volterra noise whitening and interpolation of the neighbouring fetal TOCDS samples.

MUSIC-based bispectrum detector: a novel non-invasive detection method for overlapping fetal and mother ECG signals

Walid Zgallai, M. Sabry-Rizk, Paul Hardiman +1 more

Signal Processing · UCL Discovery (University College London) · · cited 8× · DOI ↗ · more like this ·

This paper describes a novel detection method which utilises some 3-d unique bispectral features peculiar to mother and fetal transabdominally measured ECG signals to detect the number of occurrences of fetal heart beats within the maternal cycle frame before and during labour. The bispectrum detector requires the MUSIC super resolution spectral estimation to pin point different resonant frequencies associated with the QRS waves in each of the mother and fetal signals. Results obtained from 15 preoperative labour cases using both non-invasive "transabdominal" and fetal scalp electrodes show that the MUSIC detection in the second-order spectral domain can recover most of the fetal heart beats particularly those occurring at the same time as the mother's. The MUSIC also enhances fetal and mother ECG resonances and their harmonics. However, at a given false alarm probability due to poor…

Virtues and vices of source separation using linear independent component analysis for blind source separation of non-linearly coupled and synchronised fetal and mother ECGs

M. Sabry-Rizk, Walid Zgallai, Alex McLean +2 more

Signal Processing · Defense Technical Information Center (DTIC) · · cited 7× · DOI ↗ · more like this ·

In this paper, we address the imminent problem which arises when researchers unjudiciously use a linear and instantaneous (memoryless) model for the source mixing structures of independent component analysis (ICA), also known as blind source separation (BSS), in pursuit of separating noisy and frequently nonstationary combined mother and fetal electrocardiogram (ECG) signals from cutaneous measurements under the following false assumptions. (1) Sensors (electrodes) are instantaneous linear mixtures of mother and fetal source signals. (2) Noise is an additive Gaussian perturbation. (3) Mother and fetal ECG signals are assumed to be stationary and linear, mutually statistically independent and statistically independent from noise. (4) Most of the second-order (SO) and fourth-order (FO) blind source separation (BSS) methods developed this last decade assume that third-order cumulants…

Higher order statistics (HOS) in signal processing: are they of any use?

M. Sabry-Rizk

Signal Processing · · cited 7× · DOI ↗ · more like this ·

The general motivation behind the use of higher order spectra in signal processing is threefold: (1) to extract information due to deviations from Guassianity, (2) to estimate the phase of non-Gaussian parametric signals, and (3) to detect and characterise the nonlinear properties of mechanisms which generate time series via phase relations of their harmonic components. The objective of this paper is twofold: first, in attempting to perform the difficult task of providing fair and useful answers to the question title against various conflicting figures of merit associated with (HOS) based digital signal processing, the paper draws some useful conclusions based on (a) some carefully selected results published in learned journals and national/internationaI conferences (1990-95), and (b) our own experience(s) in areas such as that concerning the applications of HOS to testing for…

Blind deconvolution homomorphic analysis of abnormalities in ECG signals

M. Sabry-Rizk

Signal Processing · UCL Discovery (University College London) · · cited 6× · DOI ↗ · more like this ·

This paper presents two different approaches to the problem of modelling and characterisation of the complex signal patterns observable in the electrocardiogram (ECG), with a view to open new signal domains for diagnostic purposes besides the time and frequency domains. The first approach is based on homomorphic prediction and involves the deconvolution of a non-minimum phase ECG signal into its minimum phase and maximum phase components through cepstral filtering and linear prediction of each component separately. The second approach is based on blind deconvolution and is primarily directed at utilising the Higher Order Statistics (HOS) of the ECG signal portrayed as a plant driven by a non-gaussian independent and identically distributed (iid) process and identifying both non-minimum phase and magnitude. Again, linear prediction may be employed but it is redundant to include inverse…

Modified MUSIC pseudospectral analysis reveals common uterus and fetal heart resonances during labour contractions

M. Sabry-Rizk, Walid Zgallai, E.R. Carson +3 more

Signal Processing · UCL Discovery (University College London) · · cited 4× · DOI ↗ · more like this ·

A potentially successful non-invasive on-line labor contraction and fetal monitoring technique is proposed. The authors present the high resolution spectral signatures of the uterus and fetal during normal labor contraction episodes and their intermittent periods. Also, they discuss some abnormal labor cases. Two surface electrodes aligned transversally with the umbilicus, each spaced about 10 cm away from it, have been used together with a reference limb electrode to transabdominal electromyography (TEMG). The fetal heart electrocardiogram (ECG) signals have been recorded, simultaneously, both using the surface electrode pair (intermittent periods) and a scalp electrode (deemed essential in some high-risk labor cases). Both signals have been digitized at 512 Hz and processed using a SONICAID monitor, an interface card, and a host computer. The spectral estimator uses the…

Application of higher-order cepstral techniques in problems of fetal heart signal extraction

M. Sabry-Rizk, Walid Zgallai, Paul Hardiman +1 more

Signal Processing · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · · cited 2× · DOI ↗ · more like this ·

Recently, cepstral analysis based on second order statistics and homomorphic filtering techniques have been used in the adaptive decomposition of overlapping, or otherwise, and noise contaminated ECG complexes of mothers and fetals obtained by a transabdominal surface electrodes connected to a monitoring instrument, an interface card, and a PC. Differential time delays of fetal heart beats measured from a reference point located on the mother complex after transformation to cepstra domains are first obtained and this is followed by fetal heart rate variability computations. Homomorphic filtering in the complex cepstral domain and the subuent transformation to the time domain results in fetal complex recovery. However, three problems have been identified with second-order based cepstral techniques that needed rectification in this paper. These are (1) errors resulting from the phase…