arXiv.itsnick.co

an independent field guide to 23 million papers from arXiv & OpenAlex — not affiliated with arXiv.org

Author

G Collaboration

8 papers · 2017–2026

2017: 12018: 02019: 12020: 12021: 12022: 12023: 02024: 02025: 12026: 2
2017peak 2 in 20262026

Frequent co-authors

Papers

showing 1–8 of 8 RSS

The Radio Neutrino Observatory in Greenland (RNO-G) - System Design and Instrumentation

G Collaboration, Steven Barwick, AJ Nielsen

astro-ph.IM · · cited 0× · arXiv ↗ · more like this ·

The Radio Neutrino Observatory in Greenland (RNO-G) is designed to measure cosmic neutrinos in the EeV range through an array of radio antennas detecting nanosecond-long radio flashes. In this contribution, the RNO-G electronic system is outlined, illustrating how signals are measured from the antennas to the recorded pulses. We present new instrumentation developments, focusing on electric melters to install LPDA antennas into the Greenlandic ice sheet. The new system will simplify deployment and reduce positioning uncertainty to $\pm$2cm (x/y) and $\pm$1°(rotational). We report on field tests from the RNO-G site at Summit Station.

The beamformed trigger of RNO-G: its design and in-field performance

G Collaboration, S. Agarwal, J. A. Aguilar +76 more

astro-ph.IM · · arXiv ↗ · more like this ·

The Radio Neutrino Observatory in Greenland (RNO-G) is a neutrino detector under construction at Summit Station, with 8 out of a planned 35 stations currently deployed. We have designed and deployed a new phased array (PA) trigger based on delay-and-sum beamforming and power integration. This trigger improves detector performance by suppressing thermal noise and better targeting neutrino-induced Askaryan signals. The new PA trigger has been deployed since the 2025 season. The trigger performance has been characterized using test pulses and calibration pulsers both in the lab and in-situ, and we find across these tests a 25% average reduction in the signal-to-noise ratio (SNR) needed to trigger on signals. Simulations are shown to be representative of the detector, and simulated trigger efficiencies are within 10% of measured data. Following the in-situ trigger validation, we use…

Radio emission from airplanes as observed with RNO-G

G Collaboration, S. Agarwal, J. A. Aguilar +79 more

hep-ex · · arXiv ↗ · more like this ·

This paper describes how intentional and unintentional radio emission from airplanes is recorded with the Radio Neutrino Observatory Greenland (RNO-G). We characterize the received signals and define a procedure to extract a clean set of impulsive signals. These signals are highly suitable for instrument calibration, also for future experiments. A set of signals is used to probe the timing precision of RNO-G in-situ, which is found to match expectations. We also discuss the impact of these signals on the ability to detect neutrinos with RNO-G.

Measurements of the ionization efficiency of protons in methane

G Collaboration, L. Balogh, C. Beaufort +40 more

physics.ins-det · · arXiv ↗ · more like this ·

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume…

Solar Kaluza-Klein axion search with NEWS-G

G collaboration, Q. Arnaud, L. Balogh +39 more

hep-ex · · arXiv ↗ · more like this ·

Kaluza-Klein (KK) axions appear in theories with extra dimensions as higher mass, significantly shorter lifetime, excitations of the Peccei-Quinn axion. When produced in the Sun, they would remain gravitationally trapped in the solar system, and their decay to a pair of photons could provide an explanation of the solar corona heating problem. A low-density detector would discriminate such a signal from the background, by identifying the separation of the interaction point of the two photons. The NEWS-G collaboration uses large volume Spherical Proportional Counters, gas-filled metallic spheres with a spherical anode in their centre. After observation of a single axionlike event in a 42 day long run with the SEDINE detector, a $90\%$ C.L. upper limit of $g_{aγγ}<8.99\cdot10^{-13}\,GeV^{-1}$ is set on the axion-photon coupling for a KK axion density on Earth of…

Copper electroplating for background suppression in the NEWS-G experiment

G Collaboration, L. Balogh, C. Beaufort +47 more

physics.ins-det · · arXiv ↗ · more like this ·

New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a…

Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment

G Collaboration, Q. Arnaud, J. -P. Bard +36 more

physics.ins-det · · arXiv ↗ · more like this ·

Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of…

First results from the NEWS-G direct dark matter search experiment at the LSM

G Collaboration, Q. Arnaud, D. Asner +33 more

astro-ph.IM · · arXiv ↗ · more like this ·

New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the spin-independent WIMP-nucleon scattering cross-section in the sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times \mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5 $\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to be…