arXiv.itsnick.co

an independent field guide to 23 million papers from arXiv & OpenAlex — not affiliated with arXiv.org

Author

B. Crowe

20 papers · 1928–2026

1967: 01968: 01969: 01970: 01971: 01972: 01973: 01974: 01975: 01976: 01977: 01978: 01979: 01980: 01981: 01982: 01983: 01984: 01985: 01986: 11987: 01988: 01989: 01990: 01991: 01992: 01993: 01994: 01995: 01996: 01997: 01998: 01999: 02000: 02001: 02002: 02003: 02004: 02005: 02006: 02007: 02008: 02009: 02010: 12011: 02012: 02013: 02014: 02015: 02016: 02017: 12018: 02019: 12020: 12021: 32022: 22023: 02024: 02025: 02026: 8
1967peak 8 in 20262026

Frequent co-authors

Papers

showing 1–20 of 20 RSS

New Neutron Polarizabilities from Deuterium Compton Scattering at HI$γ$S

D. Godagama, M. W. Ahmed, B. Crowe +19 more

nucl-ex · · cited 0× · arXiv ↗ · more like this ·

Elastic and inelastic Compton-scattering cross sections of the deuteron were measured at HI$γ$S using a circularly polarized, quasi-monoenergetic $γ$-ray beam (61.0 MeV). Scattered $γ$ rays from a liquid deuterium target were detected at $55^\circ$, $115^\circ$, and $150^\circ$. High-resolution NaI(Tl) detectors at backward angles enabled separation of elastic and inelastic events. A $χ$EFT analysis of the data yields new neutron scalar polarizabilities, $α^n_{E1} = 12.25 \pm 1.1\mathrm{(stat)} \pm 0.3\mathrm{(BSR)} \pm 0.8\mathrm{(th)}$ and $β^n_{M1} = 2.95 \mp 1.1\mathrm{(stat)} \mp 0.3\mathrm{(BSR)} \mp 0.8\mathrm{(th)}$ (in units of $10^{-4} \mathrm{fm}^3$) reducing statistical uncertainties by 12 %.

First Measurement of Compton Scattering on $^3\text{He}$ at HI$γ$S

J. Zhou, E. Mancil, M. W. Ahmed +27 more

nucl-ex · · cited 0× · arXiv ↗ · more like this ·

The world's first Compton scattering measurements on a $^3$He target were performed to probe neutron electromagnetic polarizabilities. Differential cross sections were measured at laboratory angles of $40^\circ$, $55^\circ$, $90^\circ$, $115^\circ$, $150^\circ$, using circularly polarized, quasi-monoenergetic photon beams at weighted mean energy values of 61.5 and 97.1 MeV from the High Intensity $γ$-ray Source at the Triangle Universities Nuclear Laboratory. Comparisons with chiral effective field theory show good agreement at 97.1 MeV but over-prediction at 61.5 MeV, motivating further theoretical development.

A Fluorescent Hsp90 Probe Demonstrates the Unique\nAssociation between Extracellular Hsp90 and Malignancy <i>in\nVivo</i>

Lauren B. Crowe (3774958), Philip F. Hughes (1867261), David A. Alcorta (3774955) +9 more

Artificial Intelligence · Figshare · · cited 0× · DOI ↗ · more like this ·

Extracellular expression of heat\nshock protein 90 (eHsp90) by tumor cells is correlated with malignancy.\nDevelopment of small molecule probes that can detect eHsp90 <i>in vivo</i> may therefore have utility in the early detection\nof malignancy. We synthesized a cell impermeable far-red fluorophore-tagged\nHsp90 inhibitor to target eHsp90 <i>in vivo</i>. High resolution\nconfocal and lattice light sheet microscopy show that probe-bound\neHsp90 accumulates in punctate structures on the plasma membrane of\nbreast tumor cells and is actively internalized. The extent of internalization\ncorrelates with tumor cell aggressiveness, and this process can be\ninduced in benign cells by overexpressing p110HER2. Whole body cryoslicing,\nimaging, and histology of flank and spontaneous tumor-bearing mice\nstrongly suggests that eHsp90 expression and internalization is…

Intra-speaker analysis of the nasal consonant [m]

Herbert J. Oyer, Yuanwei Qi, Claude Lambert +1 more

Artificial Intelligence · The Journal of the Acoustical Society of America · · cited 0× · DOI ↗ · more like this ·

The acoustic spectrum of the nasal consonant [m] was analyzed from utterances of subjects as they produced it (1) in monosyllables, (2) in the reading of a paragraph, and (3) in attempts to disguise their voices while speaking a sentence. Findings indicate that although there is considerable intra-subject variability in the overall spectrum of the [m] consonant, the first formant remains remarkably constant. LPC analysis was employed in extracting acoustic characteristics. The results of this study have implications for speaker identification.

A Teacher looks at the County Library: An Address

W.B. CROWE

Library and Information Sciences · Library Review · · cited 0× · DOI ↗ · more like this ·

IF you are as tired hearing about the function of the library as we teacher‐librarians are of hearing about the function of the school I shall do well not to make any reference to it: for it seems that if there is a wave of juvenile crime, the school is not fulfilling its function: if business men cannot get typists to add and spell accurately, the school is not fulfilling its function: if road accidents increase, if the churches are empty, if the landworkers are drifting to the towns—the school isn't fulfilling its function. Frankly, one looks forward to the time when with the help of the county libraries the school will begin to shoulder all its responsibilities!

William Crow

P. B. Crowe

Political Science and International Relations · Notes and Queries · · cited 0× · DOI ↗ · more like this ·

Journal Article William Crow Get access P. B. Crowe P. B. Crowe Search for other works by this author on: Oxford Academic Google Scholar Notes and Queries, Volume CLV, Issue dec15, 15 December 1928, Page 427, https://doi.org/10.1093/nq/CLV.dec15.427 Published: 15 December 1928

Diversity, Equity and Inclusivity in the Australian and New Zealand Medical Physics Workforce

Emily Simpson-Page, Megan Anderson, Scott B. Crowe +4 more

physics.ed-ph · · arXiv ↗ · more like this ·

The consideration of diversity, equity and inclusivity (DEI) is an important part of promoting a robust and respectful workforce, and is critical to the continued success of organisations, including healthcare providers, academic institutions and professional societies. Many professional bodies representing medical physicists have made commitments to DEI principles in the form of mission statements, policies, steering groups, frameworks and workforce surveys. In the Australian and New Zealand medical physics community, DEI work has included reflecting on the impact of stereotypes, surveys on workforce experiences, and capturing workforce diversity metrics (including gender, nationality, age and professional background). These projects have been conducted with the support of the Australasian College of Physical Sciences and Engineering in Medicine (ACPSEM) and have contributed to the…

Magnetic resonance imaging assessment of the suitability and consistency of radiotherapy treatment positioning achieved using intra-oral stents

Tanya Kairn, Philip Chan, Benjamin Chua +7 more

physics.med-ph · · arXiv ↗ · more like this ·

As head-and-neck radiotherapy treatments grow more complex and precise, it becomes increasingly important to assess the anatomical separations that can be achieved using intra-oral stents. A series of twenty T2-weighted turbo spin echo magnetic resonance images (MRI) were acquired of one healthy participant, with a range of different wax and 3D printed intra-oral stents in situ. The resulting measurements showed that a 3D printed modular stent containing hard polylactic acid (PLA) and flexible thermoplastic polyurethane (TPU) components made the largest and most reproducible separation between the cheeks (70.8 +/- 0.3 mm), two hard PLA stents designed to exactly fit the participant's teeth produced the poorest positioning reproducibility (standard deviations of up to 3 mm between a range of landmarks measured in repeated images). Most stents were described as ``comfortable'' although…

Generation of synthetic CT images from optical scanning for superficial mold brachytherapy

Scott B. Crowe, Emily Simpson-Page, Jenna Luscombe +2 more

physics.med-ph · · arXiv ↗ · more like this ·

Optical 3D scanning systems allow the acquisition of accurate models of patient anatomy, suitable for use in the design of simple 3D-printable patient-matched medical devices with 3D modelling software. This study developed and demonstrated the use of superficial brachytherapy surface mold design workflow that utilizes data from optical 3D surface scanning and enables a commercial brachytherapy treatment planning system to be used for catheter positioning and dose optimization steps. Synthetic CT images were generated from 14 optically scanned anatomical models of human participants. Models and skin textures ac-quired from the optical scans were imported into Autodesk Meshmixer, where the treatment area was delineated, and treatment and device volumes produced. 3D Slicer was used to convert the body, treatment and device volumes to DICOM CT and RTSTRUCT data. The synthetic CT data and…

Characteristics of a 9 MeV electron beam for total skin electron radiotherapy evaluated in comparison to a 6 MeV electron beam

Tanya Kairn, Craig M. Lancaster, Scott B. Crowe

physics.med-ph · · arXiv ↗ · more like this ·

Characteristics of a 9 MeV electron beam were investigated, to evaluate potential benefits for patients with extensive mycosis fungoides lesions that are deeper than commonly treated with 6 MeV total skin electron therapy (TSET or TSE/TSEI/TSEB/TSEBT). A comprehensive commissioning measurement program was completed for TSET delivery using high-dose-rate 6 MeV and 9 MeV electron beams from a Varian TrueBeam linac. Various phantoms and dosimeters were set up 300 cm from isocenter, behind a 6 mm PMMA spoiler screen, and used for optimising beam-pair gantry angles, measuring depth-dose, lateral and horizontal profiles and B-factors, as well as performing end-to-end tests. The key clinical distinctions observed for the 9 MeV TSET beam pair compared to the 6 MeV TSET beam pair were that the 80% dose depth increased to nearly 1 cm and the practical range increased to 3.5 cm, while the maximum…

Adapting a 3D scanning water phantom for use in brachytherapy dosimetry

Rachael Wilks, Samuel C. Peet, Tanya Kairn +1 more

physics.med-ph · · arXiv ↗ · more like this ·

In external beam radiotherapy, 3D scanning water phantoms are the gold standard for obtaining relative dosimetry data. These phantoms, consisting of a water tank and mechanical arm, along with accompanying software, are de-signed to acquire dose profiles along and orthogonal to the beam axis. In brachy-therapy, the acquisition of analogous dose profiles is more difficult, and is generally achieved with complex custom-built phantoms or chemical dosimeters such as film or gel. In this study, a low-cost 3D-printed jig was designed and fabricated within a clinical department, to allow precise brachytherapy dose measurements using a PTW BeamScan water phantom. Specifically, this jig al-lowed applicators to be suspended securely and reproducibly within the water phantom. Protocols were developed to relate the scanning system coordinates to the physical source position, and to obtain isodose…

Patient-specific immobilisation for radiotherapy treatment of extensive lower-limb carcinoma

Tanya Kairn, Tania Poroa, Jenna Luscombe +3 more

physics.med-ph · · arXiv ↗ · more like this ·

When non-melanoma skin cancers extend over large areas of skin, effective radiotherapy treatments can be delivered using volumetric modulated arc therapy (VMAT) beams with narrow segments that rotate around the affected surfaces. For lower-limb carcinoma treatments, careful immobilisation is needed to achieve the degree of reproducible and stable positioning required to ensure the narrow field segments treat the targeted tissue and avoid underlying anatomy. To meet this need, a 3D printed patient-specific foot support was created in the form of a solid box containing a deep ``footprint'', shaped to match the outline of the patient's relaxed foot when lying supine, supported by a vacuum bag. For our first patient treated with a 3D printed foot support, image guidance data and clinical notes were evaluated against corresponding information from all recent lower-leg VMAT treatments. The…

Proton Compton Scattering from Linearly Polarized Gamma Rays

X. Li, M. W. Ahmed, A. Banu +27 more

nucl-ex · · arXiv ↗ · more like this ·

Differential cross sections for Compton scattering from the proton have been measured at scattering angles of $55^\circ$, $90^\circ$, and $125^\circ$ in the laboratory frame using quasimonoenergetic linearly (circularly) polarized photon beams with a weighted mean energy value of 83.4\,MeV (81.3\,MeV). These measurements were performed at the High Intensity Gamma-Ray Source facility at the Triangle Universities Nuclear Laboratory. The results are compared to previous measurements and are interpreted in the chiral effective field theory framework to extract the electromagnetic dipole polarizabilities of the proton, which gives $α_{E1}^p = 13.8\pm1.2_{\rm stat}\pm0.1_{\rm BSR}\pm0.3_{\rm theo}, β_{M1}^p = 0.2\mp1.2_{\rm stat}\pm0.1_{\rm BSR}\mp0.3_{\rm theo}$ in units of 10$^{-4}$\, fm$^3$.

Deeply virtual Compton scattering cross section at high Bjorken $x_B$

F. Georges, M. N. H. Rashad, A. Stefanko +159 more

hep-ph · · arXiv ↗ · more like this ·

We report high-precision measurements of the Deeply Virtual Compton Scattering (DVCS) cross section at high values of the Bjorken variable $x_B$. DVCS is sensitive to the Generalized Parton Distributions of the nucleon, which provide a three-dimensional description of its internal constituents. Using the exact analytic expression of the DVCS cross section for all possible polarization states of the initial and final electron and nucleon, and final state photon, we present the first experimental extraction of all four helicity-conserving Compton Form Factors (CFFs) of the nucleon as a function of $x_B$, while systematically including helicity flip amplitudes. In particular, the high accuracy of the present data demonstrates sensitivity to some very poorly known CFFs.

A Publicly Available Dataset of Out-of-Field Dose Profiles of a 6 MV Linear Accelerator

Samuel C. Peet, Naasiha Cassim, Tanya Kairn +2 more

physics.med-ph · · arXiv ↗ · more like this ·

An increase in radiotherapy-induced secondary malignancies has led to recent developments in analytical modelling of out-of-field dose. These models must be validated against measurements, but currently available datasets are outdated or limited in scope. This study aimed to address these shortcomings by producing a large dataset of out-of-field dose profiles measured with modern equipment. A novel method was developed with the intention of allowing physicists in all clinics to perform these measurements themselves using commonly available dosimetry equipment. A standard 3D scanning water tank was used to collect 36 extended profiles. Each profile was measured in two sections, with the inner section measured with the beam directly incident on the tank, and the outer section with the beam incident on a water-equivalent phantom abutted next to the tank. The two sections were then stitched…

Measuring foetal dose from tomotherapy treatments

Samuel C. Peet, Tanya Kairn, Craig M. Lancaster +3 more

physics.med-ph · · arXiv ↗ · more like this ·

Introduction: Treating pregnant women in the radiotherapy clinic is a rare occurrence. When it does occur, it is vital that the dose received by the developing embryo or foetus is understood as fully as possible. This study presents the first investigation of foetal doses delivered during helical tomotherapy treatments. Materials & Methods: Six treatment plans were delivered to an anthropomorphic phantom using a tomotherapy machine. These included treatments of the brain, unilateral and bilateral head-and-neck, chest wall, and upper lung. Measurements of foetal dose were made with an ionisation chamber positioned at various locations longitudinally within the phantom to simulate a variety of patient anatomies. Results: All measurements were below the established limit of 100 mGy for a high risk of damage during the first trimester. The largest dose encountered was 75 mGy (0.125% of…

Form Factors and Two-Photon Exchange in High-Energy Elastic Electron-Proton Scattering

M. E. Christy, T. Gautam, L. Ou +167 more

nucl-ex · · arXiv ↗ · more like this ·

We present new precision measurements of the elastic electron-proton scattering cross section for momentum transfer (Q$^2$) up to 15.75~\gevsq. Combined with existing data, these provide an improved extraction of the proton magnetic form factor at high Q$^2$ and double the range over which a longitudinal/transverse separation of the cross section can be performed. The difference between our results and polarization data agrees with that observed at lower Q$^2$ and attributed to hard two-photon exchange (TPE) effects, extending to 8~(GeV/c)$^2$ the range of Q$^2$ for which a discrepancy is established at $>$95\% confidence. We use the discrepancy to quantify the size of TPE contributions needed to explain the cross section at high Q$^2$.

Deep exclusive electroproduction of $π^0$ at high $Q^2$ in the quark valence regime

The Jefferson Lab Hall A Collaboration, M. Dlamini, B. Karki +159 more

hep-ex · · arXiv ↗ · more like this ·

We report measurements of the exclusive neutral pion electroproduction cross section off protons at large values of $x_B$ (0.36, 0.48 and 0.60) and $Q^2$ (3.1 to 8.4 GeV$^2$) obtained from Jefferson Lab Hall A experiment E12-06-014. The corresponding structure functions $dσ_L/dt+εdσ_T/dt$, $dσ_{TT}/dt$, $dσ_{LT}/dt$ and $dσ_{LT'}/dt$ are extracted as a function of the proton momentum transfer $t-t_{min}$. The results suggest the amplitude for transversely polarized virtual photons continues to dominate the cross-section throughout this kinematic range. The data are well described by calculations based on transversity Generalized Parton Distributions coupled to a helicity flip Distribution Amplitude of the pion, thus providing a unique way to probe the structure of the nucleon.

Compton scattering from $^4$He at the TUNL HI$γ$S facility

X. Li, M. W. Ahmed, A. Banu +26 more

nucl-ex · · arXiv ↗ · more like this ·

Differential cross sections for elastic Compton scattering from $^4$He have been measured with high statistical precision at the High Intensity $γ$-ray Source at laboratory scattering angles of $55^\circ$, $90^\circ$, and $125^\circ$ using a quasi-monoenergetic photon beam with a weighted mean energy value of $81.3$ MeV. The results are compared to previous measurements and similar fore-aft asymmetry in the angular distribution of the differential cross sections is observed. This experimental work is expected to strongly motivate the development of effective-field-theory calculations of Compton scattering from $^4$He to fully interpret the data.

Measurements of the Electric Form Factor of the Neutron up to Q2=3.4 GeV2 using the Reaction He3(e,e'n)pp

S. Riordan, S. Abrahamyan, B. Craver +115 more

nucl-ex · · arXiv ↗ · more like this ·

The electric form factor of the neutron was determined from studies of the reaction He3(e,e'n)pp in quasi-elastic kinematics in Hall A at Jefferson Lab. Longitudinally polarized electrons were scattered off a polarized target in which the nuclear polarization was oriented perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with neutrons that were registered in a large-solid-angle detector. More than doubling the Q2-range over which it is known, we find GEn = 0.0225 +/- 0.0017 (stat) +/- 0.0024 (syst), 0.0200 +/- 0.0023 +/- 0.0018, and 0.0142 +/- 0.0019 +/- 0.0013 for Q2 = 1.72, 2.48, and 3.41 GeV2, respectively.