arXiv.itsnick.co

an independent field guide to 23 million papers from arXiv & OpenAlex — not affiliated with arXiv.org

Author

Alberto Redaelli

21 papers · 2017–2026

2017: 12018: 02019: 12020: 02021: 12022: 32023: 32024: 32025: 42026: 5
2017peak 5 in 20262026

Frequent co-authors

Papers

showing 1–21 of 21 RSS

The use of mixed reality for the treatment planning of unruptured intracranial aneurysms

Vito Stifano, Maria Chiara Palumbo, Swathi Chidambaram +6 more

Computer Vision and Pattern Recognition · Journal of Neurosurgical Sciences · · cited 16× · DOI ↗ · more like this ·

BACKGROUND: A thorough comprehension of topographic neuroanatomy is paramount in neurosurgery. In recent years, great attention has been raised towards extended reality, which comprises virtual, augmented, and mixed reality (MR) as an aid for surgery. In this paper, we describe our preliminary experience with the use of a new MR platform, aiming to assess its reliability and usefulness in the planning of surgical treatment of unruptured intracranial aneurysms. METHODS: We prospectively enrolled 5 patients, harboring a total of 8 intracranial unruptured aneurysms, undergoing elective surgical clipping. A wearable mixed-reality device (HoloLens; Microsoft Corp., Redmond, WA, USA) was used to display and interact with a holographic model during surgical planning. Afterward, a total of 10 among surgeons and residents filled in a 5-point Likert-Scale evaluation questionnaire. RESULTS…

Augmented Reality and Human-Robot Collaboration Framework for Percutaneous Nephrolithotomy: System Design, Implementation, and Performance Metrics

Junling Fu, Matteo Pecorella, Elisa Iovene +5 more

cs.RO · · cited 15× · arXiv ↗ · more like this ·

During Percutaneous Nephrolithotomy (PCNL) operations, the surgeon is required to define the incision point on the patient's back, align the needle to a pre-planned path, and perform puncture operations afterward. The procedure is currently performed manually using ultrasound or fluoroscopy imaging for needle orientation, which, however, implies limited accuracy and low reproducibility. This work incorporates Augmented Reality (AR) visualization with an optical see-through head-mounted display (OST-HMD) and Human-Robot Collaboration (HRC) framework to empower the surgeon's task completion performance. In detail, Eye-to-Hand calibration, system registration, and hologram model registration are performed to realize visual guidance. A Cartesian impedance controller is used to guide the operator during the needle puncture task execution. Experiments are conducted to verify the system…

The MAORY/MORFEO MAIT strategy in Europe

Jacopo Farinato, Luca Marafatto, Gabriele Rodeghiero +9 more

Political Science and International Relations · Adaptive Optics Systems VIII · · cited 3× · DOI ↗ · more like this ·

MAORY stands for Multi-conjugate Adaptive Optics RelaY (the name has been recently changed to MORFEO, which stands for Multiconjugate adaptive Optics For ELT Observations, thus in this article we will use MORFEO), and it is one of the instruments of the European Extremely Large Telescope (ELT). The main function of MORFEO is to relay the light beam from the ELT focal plane to the client instrument (initially MICADO) while compensating, through a multiconjugate adaptive optics system, the effects of the atmospheric turbulence and other disturbances affecting the wavefronts coming from the scientific sources of interest. The MORFEO instrument is designed and developed by a European consortium composed of INAF (Istituto Nazionale di AstroFisica, Italy), CNRS/INSU (Centre National de la Recherche Scientifique/ Institut National des Sciences de l’Univers, France), NUIG (National University…

A MiXed-Reality automatic system for enhanced precision in craniotomy procedure for meningioma resection: A multicentric study

Alessandro Albanesi, Marco Schiariti, Fabio Morelli +9 more

Computer Vision and Pattern Recognition · Computer Methods and Programs in Biomedicine · · cited 0× · DOI ↗ · more like this ·

BACKGROUND AND OBJECTIVE: Craniotomy is the standard surgical approach in neuro-oncology for accessing and removing brain tumors. Despite being the clinical gold standard, conventional image-guided systems such as neuronavigation platforms suffer from high costs, limited ergonomics, and 2D visual constraints that can hinder surgical precision and usability. This study presents and validates a standalone mixed reality system for automatic craniotomy planning and intra-operative guidance, designed to provide an ergonomic, cost-effective, and intuitive alternative to traditional neuronavigation. METHODS: The system, composed of a laptop and a HoloLens 2 headset, integrates automatic craniotomy planning, hologram-to-patient registration, and real-time 3D visualization. A multicentric in vitro study was conducted with ten neurosurgeons performing craniotomies on a custom 3D-printed phantom…

A Scalable AI-Powered System for Explainable Machine Learning Pipelines in Brain Tumor

Yin Lin, Elena De Martin, Giacomo Conte +6 more

cs.SE · · arXiv ↗ · more like this ·

Artificial intelligence and radiomics are increasingly used in brain tumor research, yet their translation into clinical practice remains limited by fragmented workflows, poor transparency, and weak integration with end users' needs. We present the first version of a scalable web-based visual analytics system designed to support radiomics-driven machine learning inference in neuro-oncology. The platform integrates three core functions within a single interface: cohort management from structured clinical tables, radiomic feature extraction from medical images and segmentation masks, and guarded inference with pre-trained machine learning models. The system was developed through an iterative user-centred design process and evaluated on both a public glioblastoma dataset and a proprietary clinical cohort. A key contribution is the explicit exposure of intermediate workflow artifacts, which…

Radiomics- and Clinical Feature-Driven Prediction of Volumetric Response in Skull-Base Meningioma after CyberKnife Radiosurgery

Yin Lin, Elena De Martin, Giacomo Conte +6 more

cs.CV · · arXiv ↗ · more like this ·

Skull-base meningiomas are often characterized by favorable long-term prognosis, yet their anatomical complexity and proximity to critical neurovascular structures make treatment selection challenging. Stereotactic radiosurgery with CyberKnife represents an effective therapeutic option when surgical resection is not feasible; however, not all patients benefit equally from this treatment. Early identification of patients likely to respond to radiosurgery remains an open clinical problem. In this study, we propose a radiomics- and clinical feature-driven framework for predicting volumetric response in skull-base meningiomas treated with CyberKnife. Unlike most existing approaches that focus on progression-free survival or recurrence, our method targets volumetric response as an indicator of treatment efficacy. Pre-treatment MRI images from 104 patients were processed to extract radiomic…

Touchless Intraoperative Image Access System Based on Vision-Based Hand Tracking

Yin Lin, Domenico Aquino, Alberto Redaelli +3 more

cs.CV · · arXiv ↗ · more like this ·

Touchless interaction with medical images is becoming increasingly important in the surgical field, where sterility and continuity of the operational workflow are essential requirements. This work presents a vision-based system for intraoperative navigation of medical images through hand gestures acquired using a single RGB camera. Unlike many existing solutions, the system does not require additional hardware or user-specific training. Hand tracking is performed in real time using MediaPipe Hands, which provides a 2.5D estimation of hand landmarks. Simple and intuitive gestures are then mapped into translation, rotation, and zoom commands, enabling continuous and natural interaction with the image viewer. The system architecture is independent from the visualization software and, for implementation simplicity, in this study it was integrated with PyVista. Performance was evaluated…

Physics-driven Sonification for Improving Multisensory Needle Guidance in Percutaneous Epicardial Access

Veronica Ruozzi, Sasan Matinfar, Pasquale Vergara +7 more

cs.HC · · arXiv ↗ · more like this ·

Percutaneous epicardial access (PEA), performed on a beating heart under fluoroscopy, enables arrhythmia treatment. However, advancing a needle toward the thin and moving pericardium remains highly challenging and risky. To address this problem, we present a physics-driven sonification method for Extended Reality (XR)-based multisensory navigation to enhance user perception during the critical needle landing phase in PEA. Dynamic cardiac anatomy from 4D CTA was reconstructed and registered to a real-world coordinate system. Real-time needle tracking provided the position of the needle tip relative to moving cardiac structures and drove an audio-visual feedback module. The visual display presented navigational cues and dynamic anatomy, while the auditory display encoded physiological cardiac states using a multilayer physical membrane model. A phantom study was conducted with twelve…

BioSonix: Can Physics-Based Sonification Perceptualize Tissue Deformations From Tool Interactions?

Veronica Ruozzi, Sasan Matinfar, Laura Schütz +4 more

cs.SD · · arXiv ↗ · more like this ·

Perceptualizing tool interactions with deformable structures in surgical procedures remains challenging, as unimodal visualization techniques often fail to capture the complexity of these interactions due to constraints such as occlusion and limited depth perception. This paper presents a novel approach to augment tool navigation in mixed reality environments by providing auditory representations of tool-tissue dynamics, particularly for interactions with soft tissue. BioSonix, a physics-informed design framework, utilizes tissue displacements in 3D space to compute excitation forces for a sound model encoding tissue properties such as stiffness and density. Biomechanical simulations were employed to model particle displacements resulting from tool-tissue interactions, establishing a robust foundation for the method. An optimization approach was used to define configurations for…

Glioblastoma Overall Survival Prediction With Vision Transformers

Yin Lin, Riccardo Barbieri, Domenico Aquino +5 more

cs.CV · · arXiv ↗ · more like this ·

Glioblastoma is one of the most aggressive and common brain tumors, with a median survival of 10-15 months. Predicting Overall Survival (OS) is critical for personalizing treatment strategies and aligning clinical decisions with patient outcomes. In this study, we propose a novel Artificial Intelligence (AI) approach for OS prediction using Magnetic Resonance Imaging (MRI) images, exploiting Vision Transformers (ViTs) to extract hidden features directly from MRI images, eliminating the need of tumor segmentation. Unlike traditional approaches, our method simplifies the workflow and reduces computational resource requirements. The proposed model was evaluated on the BRATS dataset, reaching an accuracy of 62.5% on the test set, comparable to the top-performing methods. Additionally, it demonstrated balanced performance across precision, recall, and F1 score, overcoming the best model in…

Pericoronary adipose tissue attenuation as a predictor of functional severity of coronary stenosis

Marta Pillitteri, Guido Nannini, Simone Saitta +5 more

eess.IV · · arXiv ↗ · more like this ·

Objective: This study aims to evaluate the functional significance of coronary stenosis by analyzing low-level radiomic features of the pericoronary adipose tissue (PCAT) surrounding the lesions, which are indicative of its inflammation status. Methods: A dataset of 72 patients who underwent coronary computed tomography angiography (CCTA) was analyzed, with 3D segmentation and computational fluid dynamics (CFD) simulations from a prior study. Centerlines of the main epicardial branches were automatically extracted, and lesions identified using Gaussian kernel regression to estimate healthy branch caliber. PCAT features were computed per vessel following guideline recommendations and per lesion within a region extending radially for two vessel radii. Features like fat volume and mean attenuation (FAI) were analyzed for their relationship with CFD-derived hemodynamic biomarkers, such as…

Learning Hemodynamic Scalar Fields on Coronary Artery Meshes: A Benchmark of Geometric Deep Learning Models

Guido Nannini, Julian Suk, Patryk Rygiel +7 more

eess.IV · · arXiv ↗ · more like this ·

Coronary artery disease, caused by the narrowing of coronary vessels due to atherosclerosis, is the leading cause of death worldwide. The diagnostic gold standard, fractional flow reserve (FFR), measures the trans-stenotic pressure ratio during maximal vasodilation but is invasive and costly. This has driven the development of virtual FFR (vFFR) using computational fluid dynamics (CFD) to simulate coronary flow. Geometric deep learning algorithms have shown promise for learning features on meshes, including cardiovascular research applications. This study empirically analyzes various backends for predicting vFFR fields in coronary arteries as CFD surrogates, comparing six backends for learning hemodynamics on meshes using CFD solutions as ground truth. The study has two parts: i) Using 1,500 synthetic left coronary artery bifurcations, models were trained to predict pressure-related…

Deep vectorised operators for pulsatile hemodynamics estimation in coronary arteries from a steady-state prior

Julian Suk, Guido Nannini, Patryk Rygiel +4 more

q-bio.QM · · arXiv ↗ · more like this ·

Cardiovascular hemodynamic fields provide valuable medical decision markers for coronary artery disease. Computational fluid dynamics (CFD) is the gold standard for accurate, non-invasive evaluation of these quantities in silico. In this work, we propose a time-efficient surrogate model, powered by machine learning, for the estimation of pulsatile hemodynamics based on steady-state priors. We introduce deep vectorised operators, a modelling framework for discretisation-independent learning on infinite-dimensional function spaces. The underlying neural architecture is a neural field conditioned on hemodynamic boundary conditions. Importantly, we show how relaxing the requirement of point-wise action to permutation-equivariance leads to a family of models that can be parametrised by message passing and self-attention layers. We evaluate our approach on a dataset of 74 stenotic coronary…

An automated and time efficient framework for simulation of coronary blood flow under steady and pulsatile conditions

Guido Nannini, Simone Saitta, Luca Mariani +5 more

physics.med-ph · · arXiv ↗ · more like this ·

Fractional flow reserve (FFR) is the gold standard for diagnosing coronary artery disease (CAD). FFRCT uses computational fluid dynamics (CFD) to evaluate FFR non-invasively by simulating coronary flow in geometries reconstructed from computed tomography (CT). However, it faces challenges related to the cost of computing and uncertainties in defining patient-specific boundary conditions (BCs). We investigated using time-averaged steady BCs instead of pulsatile ones to reduce computational time and deployed a self-adjusting method for tuning BCs to patient clinical data. 133 coronary arteries were reconstructed from CT images of CAD patients. For each vessel, invasive FFR was measured. Steady BCs for CFD were defined in two steps: i) rest BCs were extrapolated from clinical and image-derived data; ii) hyperemic BCs were computed from resting conditions. Flow rate was iteratively adjusted…

Implicit neural representations for unsupervised super-resolution and denoising of 4D flow MRI

Simone Saitta, Marcello Carioni, Subhadip Mukherjee +2 more

eess.IV · · arXiv ↗ · more like this ·

4D flow MRI is a non-invasive imaging method that can measure blood flow velocities over time. However, the velocity fields detected by this technique have limitations due to low resolution and measurement noise. Coordinate-based neural networks have been researched to improve accuracy, with SIRENs being suitable for super-resolution tasks. Our study investigates SIRENs for time-varying 3-directional velocity fields measured in the aorta by 4D flow MRI, achieving denoising and super-resolution. We trained our method on voxel coordinates and benchmarked our approach using synthetic measurements and a real 4D flow MRI scan. Our optimized SIREN architecture outperformed state-of-the-art techniques, producing denoised and super-resolved velocity fields from clinical data. Our approach is quick to execute and straightforward to implement for novel cases, achieving 4D super-resolution.

A CT-based deep learning system for automatic assessment of aortic root morphology for TAVI planning

Simone Saitta, Francesco Sturla, Riccardo Gorla +4 more

q-bio.QM · · arXiv ↗ · more like this ·

Accurate planning of transcatheter aortic implantation (TAVI) is important to minimize complications, and it requires anatomic evaluation of the aortic root (AR), commonly done through 3D computed tomography (CT) image analysis. Currently, there is no standard automated solution for this process. Two convolutional neural networks (CNNs) with 3D U-Net architectures (model 1 and model 2) were trained on 310 CT scans for AR analysis. Model 1 performed AR segmentation and model 2 identified the aortic annulus and sinotubular junction (STJ) contours. Results were validated against manual measurements of 178 TAVI candidates. After training, the two models were integrated into a fully automated pipeline for geometric analysis of the AR. The trained CNNs effectively segmented the AR, annulus and STJ, resulting in mean Dice scores of 0.93 for the AR, and mean surface distances of 1.16 mm and…

A Deep Learning-Based Fully Automated Pipeline for Regurgitant Mitral Valve Anatomy Analysis From 3D Echocardiography

Riccardo Munafò, Simone Saitta, Giacomo Ingallina +5 more

cs.CV · · arXiv ↗ · more like this ·

Three-dimensional transesophageal echocardiography (3DTEE) is the recommended imaging technique for the assessment of mitral valve (MV) morphology and lesions in case of mitral regurgitation (MR) requiring surgical or transcatheter repair. Such assessment is key to thorough intervention planning and to intraprocedural guidance. However, it requires segmentation from 3DTEE images, which is timeconsuming, operator-dependent, and often merely qualitative. In the present work, a novel workflow to quantify the patient-specific MV geometry from 3DTEE is proposed. The developed approach relies on a 3D multi-decoder residual convolutional neural network (CNN) with a U-Net architecture for multi-class segmentation of MV annulus and leaflets. The CNN was trained and tested on a dataset comprising 55 3DTEE examinations of MR-affected patients. After training, the CNN is embedded into a fully…

Data-driven generation of 4D velocity profiles in the aneurysmal ascending aorta

Simone Saitta, Ludovica Maga, Chloe Armour +8 more

q-bio.TO · · arXiv ↗ · more like this ·

Numerical simulations of blood flow are a valuable tool to investigate the pathophysiology of ascending thoracic aortic aneurysms (ATAA). To accurately reproduce hemodynamics, computational fluid dynamics (CFD) models must employ realistic inflow boundary conditions (BCs). However, the limited availability of in vivo velocity measurements still makes researchers resort to idealized BCs. In this study we generated and thoroughly characterized a large dataset of synthetic 4D aortic velocity profiles suitable to be used as BCs for CFD simulations. 4D flow MRI scans of 30 subjects with ATAA were processed to extract cross-sectional planes along the ascending aorta, ensuring spatial alignment among all planes and interpolating all velocity fields to a reference configuration. Velocity profiles of the clinical cohort were extensively characterized by computing flow morphology descriptors of…

CUBES Phase A design overview -- The Cassegrain U-Band Efficient Spectrograph for the Very Large Telescope

Alessio Zanutta, Stefano Cristiani, David Atkinson +51 more

astro-ph.IM · · arXiv ↗ · more like this ·

We present the baseline conceptual design of the Cassegrain U-Band Efficient Spectrograph (CUBES) for the Very Large Telescope. CUBES will provide unprecedented sensitivity for spectroscopy on a 8 - 10 m class telescope in the ground ultraviolet (UV), spanning a bandwidth of > 100 nm that starts at 300 nm, the shortest wavelength accessible from the ground. The design has been optimized for end-to-end efficiency and provides a spectral resolving power of R > 20000, that will unlock a broad range of new topics across solar system, Galactic and extraglactic astronomy. The design also features a second, lower-resolution (R \sim 7000) mode and has the option of a fiberlink to the UVES instrument for simultaneous observations at longer wavelengths. Here we present the optical, mechanical and software design of the various subsystems of the instrument after the Phase A study of the project.…

Simulating the optical alignment of the multiconjugate adaptive optics module for the extremely large telescope

Mauro Patti, Matteo Lombini, Edoardo Maria Alberto Redaelli +1 more

astro-ph.IM · · arXiv ↗ · more like this ·

Adaptive optics (AO) instruments for the future extremely large telescopes (ELTs) are characterized by advanced optical systems with diffraction-limited optical quality. Low geometric distortion is also crucial for high accuracy astrometric applications. Optical alignment of such systems is a crucial step of the instrument integration. Due to relative inaccessibility of these giant instruments, automatic alignment methods are also favored to improve the instrument availability after major events, such as extraordinary maintenance. The proposed alignment concept for these systems is described: the notable example which is analyzed here is the case of the multiconjugate AO relay for the future ELT. The results of ray-tracing simulations carried out to validate the method are discussed in detail, covering the error sources, which could degrade the alignment performance.

Simulation of left ventricle fluid dynamics with mitral regurgitation from magnetic resonance images with fictitious elastic structure regularization

Toni Lassila, Cristiano Malossi, Marco Stevanella +3 more

physics.med-ph · · arXiv ↗ · more like this ·

Computer modeling can provide quantitative insight into cardiac fluid dynamics phenomena that are not evident from standard imaging tools. We propose a new approach to modeling left ventricle fluid dynamics based on an image-driven model-based description of ventricular motion. In this approach, the end-diastolic geometry and time-dependent deformation of the left ventricle cavity are obtained from cardiac magnetic resonance images and a fictitious elastic structure is used to impose the contractile behavior of the left ventricle. This allows seamless treatment of the isovolumic phases. Besides the ventricular motion, the intracavitary fluid dynamics is controlled by the mitral valve. Three different mitral valve models are included in the simulation: an idealized diode (with or without regurgitation) and a lumped parameter model accounting for the opening dynamics of the valve and…