Computer Science · Signal Processing
A procedure for calibrating ear canals at high frequencies
D. M. Green, Κ. Ν. Stevens, Robert Berkovitz, A. Derr, M. Krasner, Robert W. Pyle
See on the mapAbstract
A system for delivering a sinusoidal signal of known sound pressure to the ear at high frequencies (8–20 kHz) is explored. A high-frequency driver unit is coupled to the ear canal through a long tube, so that the acoustic source at the ear-canal entrance had an impedance close to ρc. The system is calibrated by applying an impulse of voltage to the source and measuring the response at a small microphone located in the coupling tube close to the ear-canal entrance. A signal-processing procedure detects the zeros in the spectrum of this response and uses these data to estimate the transfer function from the source voltage to the sound pressure at the inner end of the ear canal. The system has been calibrated for a number of different ears in this way, and data giving the range of characteristics of the ear canals as determined by the zero locations will be described. In general, the results are consistent with theoretical predictions based on the known average shape of the ear canal. [Supported by a contract from NINCDS.]