arXiv.itsnick.co

an independent field guide to 23 million papers from arXiv & OpenAlex — not affiliated with arXiv.org

Author

Timothy Whitlatch

4 papers · 2018–2020

2018: 12019: 12020: 2
2018peak 2 in 20202020

Frequent co-authors

Papers

showing 1–4 of 4 RSS

Strange Hadron Spectroscopy with Secondary KL Beam in Hall D

KLF Collaboration, Moskov Amaryan, Mikhail Bashkanov +150 more

nucl-ex · · arXiv ↗ · more like this ·

We propose to create a secondary beam of neutral kaons in Hall D at Jefferson Lab to be used with the GlueX experimental setup for strange hadron spectroscopy. The superior CEBAF electron beam will enable a flux on the order of $1\times 10^4~K_L/sec$, which exceeds the flux of that previously attained at SLAC by three orders of magnitude. The use of a deuteron target will provide first measurements ever with neutral kaons on neutrons. The experiment will measure both differential cross sections and self-analyzed polarizations of the produced $Λ$, $Σ$, $Ξ$, and $Ω$ hyperons using the GlueX detector at the Jefferson Lab Hall D. The measurements will span CM $\cosθ$ from $-0.95$ to 0.95 in the range W = 1490 MeV to 2500 MeV. The new data will significantly constrain the partial wave analyses and reduce model-dependent uncertainties in the extraction of the properties and pole positions of…

Conceptual Design of Beryllium Target for the KLF Project

Igor Strakovsky, Moskov Amaryan, Mikhail Bashkanov +8 more

physics.ins-det · · arXiv ↗ · more like this ·

The Kaon Production Target (KPT) is an important component of the proposed K-Long facility which will be operated in JLab Hall~D, targeting strange baryon and meson spectroscopy. In this note we present a conceptual design for the Be-target assembly for the planned K-Long beam line, which will be used along with the GlueX spectrometer in its standard configuration for the proposed experiments. The high quality 12-GeV CEBAF electron beam enables production of a K$_L$ flux at the GlueX target on the order of $1\times 10^4 K_L/sec$, which exceeds the K$_L$ flux previously attained at SLAC by three orders of magnitude. An intense K$_L$ beam would open a new window of opportunity not only to locate "missing resonances" in the strange hadron spectrum, but also to establish their properties by studying different decay channels systematically. The most important and radiation damaging…

The GlueX Start Counter Detector

Eric Pooser, Fernando Barbosa, Werner Boeglin +11 more

physics.ins-det · · arXiv ↗ · more like this ·

The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.

Construction and Performance of the Barrel Electromagnetic Calorimeter for the GlueX Experiment

Tegan Beattie, Ahmed Foda, Colleen Henschel +36 more

physics.ins-det · · arXiv ↗ · more like this ·

The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected…