Physics · physics.ins-det
Proposal for a Hadron Blind Detector for PHENIX
A. Kozlov, C. Aidala, B. Azmoun, Z. Fraenkel, T. Hemmick, B. Khachaturov, A. Milov, I. Ravinovich, I. Tserruya, S. Stoll, C. Woody, S. Zhou
See on the mapAbstract
A Hadron Blind Detector (HBD) is proposed as upgrade of the PHENIX detector at RHIC, BNL. The HBD will allow the measurement of low-mass e+e- pairs from the decay of the light vector mesons rho, omega, phi and the low-mass continuum in Au-Au collisions at energies up to sqrt{s_{NN}}= 200 GeV. From MC simulations and general considerations, the HBD has to identify electrons with very high efficiency (> 90%), double hit recognition better than 90%, moderate pion rejection factor of ~200 and radiation budget of the order of 1% of a radiation length. The first choice under study is a windowless Cherenkov detector, operated with pure CF4, in a special proximity focus configuration with a CsI photocathode and a multistage GEM amplification element.
References
0 of 14 references are in the index.
Cited by
No paper in the index cites this yet (Semantic Scholar counts 8 in total).
The cited-by list is still filling in while reference lists are collected.